Product information "Victron - Lithium Superpack 12.8V/200AH"
Lithium battery for direct exchange as a replacement for lead batteries in 12 V systems.
Integrated BMS and safety switch
The Superpack batteries are extremely easy to install and no additional components are required.
The internal switch separates the batteries in the event of a deep discharge, overload or too high temperature.
Protected against improper use
In the following cases, a lead-acid battery is failed prematurely due to sulfating:
• If it is in operation for a long time in insufficiently charged condition (e.g. the battery is rarely or never fully charged).
• If it is left in a partially discharged or worse, completely unloaded state.
A lithium-ion battery does not have to be fully charged. The operating life increases even easily if the battery is only partially charged instead of fully.
This is a significant advantage of lithium-ion batteries compared to lead-acid batteries.
The superpack batteries interrupt the loading or Unlike current when the maximum nominal values are exceeded.
Efficient
In the case of numerous possible uses (especially for network-independent solar systems), the level of energy use can be of decisive importance.
The level of energy use of a charging cycle (unloading 100 % to 0 % and recharging to 100 %) of an average lead-acid battery is approx. 80 %.
However, the level of energy use of a charging cycle of a lithium-ion battery is 92 %.
The loading process of a lead-acid battery becomes particularly inefficient when the 80 %mark of the state of charge has been reached.
This leads to levels of energy use of only 50 %. In the case of solar systems, this value is even lower, as energy reserves are required for several days (the battery is between 70 % and 100 % in a charging status).
A lithium-ion battery, on the other hand, still achieves an energy use level of 90 %, even if it is in a flat unloading state.
Can be switched in parallel
The batteries can be switched in parallel. A series connection is not permitted.
Use only in an upright position.
Chemistry Lifepo4
Nominal voltage 12.8V
Nominal capacity at 25 ° C 200AH
Nominal capacity at 0 ° C 160AH
Nominal capacity at 25 ° C 2560Wh
Life cycle at 80 % deep discharge and 25 ° C 2500 cycles
Maximum contin. Discharge stream 70a
Top value discharge flow (10 s) 100a
Discharge tension 10V
"Constant" charging voltage (absorption) ** 14.2V-14.4V
"Conservation" charging voltage (float) 13.5V
Maximum contin. Charging current 70a
Parallel circuit yes, unlimited
Series circuit no
Operating temperature discharge: -10 ° C to +50 ° C charge: +5 ° C to +45 ° C
Storage temperature maximum storage time at full load moist (non -condensing) -40 ° C to +65 ° C
Protection class IP 43
Power closure (threaded bushes) M8
Dimensions (LXBXH) 520 x 269 x 208mm
Weight 32kg
** At best, the constant voltage period should not be longer than 4 hours. A longer constant voltage phase can easily reduce the lifespan of the battery.
. This article is a blocking goods. Due to the size, weight or nature of the article, there are additional shipping costs in this case, which are also calculated.
Integrated BMS and safety switch
The Superpack batteries are extremely easy to install and no additional components are required.
The internal switch separates the batteries in the event of a deep discharge, overload or too high temperature.
Protected against improper use
In the following cases, a lead-acid battery is failed prematurely due to sulfating:
• If it is in operation for a long time in insufficiently charged condition (e.g. the battery is rarely or never fully charged).
• If it is left in a partially discharged or worse, completely unloaded state.
A lithium-ion battery does not have to be fully charged. The operating life increases even easily if the battery is only partially charged instead of fully.
This is a significant advantage of lithium-ion batteries compared to lead-acid batteries.
The superpack batteries interrupt the loading or Unlike current when the maximum nominal values are exceeded.
Efficient
In the case of numerous possible uses (especially for network-independent solar systems), the level of energy use can be of decisive importance.
The level of energy use of a charging cycle (unloading 100 % to 0 % and recharging to 100 %) of an average lead-acid battery is approx. 80 %.
However, the level of energy use of a charging cycle of a lithium-ion battery is 92 %.
The loading process of a lead-acid battery becomes particularly inefficient when the 80 %mark of the state of charge has been reached.
This leads to levels of energy use of only 50 %. In the case of solar systems, this value is even lower, as energy reserves are required for several days (the battery is between 70 % and 100 % in a charging status).
A lithium-ion battery, on the other hand, still achieves an energy use level of 90 %, even if it is in a flat unloading state.
Can be switched in parallel
The batteries can be switched in parallel. A series connection is not permitted.
Use only in an upright position.
Chemistry Lifepo4
Nominal voltage 12.8V
Nominal capacity at 25 ° C 200AH
Nominal capacity at 0 ° C 160AH
Nominal capacity at 25 ° C 2560Wh
Life cycle at 80 % deep discharge and 25 ° C 2500 cycles
Maximum contin. Discharge stream 70a
Top value discharge flow (10 s) 100a
Discharge tension 10V
"Constant" charging voltage (absorption) ** 14.2V-14.4V
"Conservation" charging voltage (float) 13.5V
Maximum contin. Charging current 70a
Parallel circuit yes, unlimited
Series circuit no
Operating temperature discharge: -10 ° C to +50 ° C charge: +5 ° C to +45 ° C
Storage temperature maximum storage time at full load moist (non -condensing) -40 ° C to +65 ° C
Protection class IP 43
Power closure (threaded bushes) M8
Dimensions (LXBXH) 520 x 269 x 208mm
Weight 32kg
** At best, the constant voltage period should not be longer than 4 hours. A longer constant voltage phase can easily reduce the lifespan of the battery.