- Power Supply
- Conductors and Installation
- Devices and Consumers
- Boat Accessories
- New Products
€84.90*
% €99.96* (15.07% saved vs. recommended price)will be ordered for you
Lead time: 7 days (according to manufacturer**),
est. total delivery time: 1-2 weeks
Product number:
1972995
EAN:
8719076040811
Manufacturer product ID:
SCC110015060R
Please note that our English product descriptions are automatic translations from German. If anything is unclear, please contact us and/or double check the description by the manufacturer. Thanks for your understanding! - your Klabauter Crew
Product information "Victron - Smartsolar Mppt 100/15"
Built -in Bluetooth Smart: No dongle necessary
The wireless solution for set-up, monitor and updated the controller using Apple and Android smartphones, tablets or other devices.
Ve.direct
For a wired data connection with a color control panel, a PC or other devices.
Ultra -fast maximum power point tracking (mppt)
Especially when the sky is covered, when the light intensity changes, an extremely fast MPP regulator improves the energy yield compared to PWM charging controls by up to 30 % and compared to slower MPPT regulators by up to 10 %.
Load exit
An overload of the battery can be prevented by connecting all loads to the load exit.
The load exit separates the loads when the battery has been unloaded to a given voltage value.
Alternatively, an algorithm for intelligent battery management can also be selected: see BatteryLife.
The load exit is short -circuit -proof.
Battery Life: Intelligent battery management
If the solar charging controller is not able to charge the battery within one day to its full capacity, the status of the battery constantly changes between "partially charged" and "end of the discharge".
This operating mode (no regular charging) damages a lead-acid battery within a few weeks or months.
The battery algorithm monitors the charging status of the battery and, if necessary, it takes up the threshold to separate the load every day (i.e., the load is separated earlier) until the energy obtained is sufficient to charge the battery up to almost 100 %. From this point, the threshold value for switching off the load is modulated, so that the charge is almost 100 % reached about once a week.
Programmable battery charging algorithm
For more information, see the Software section on the Victron Energy website.
Day/night taxation and light insulation option
For more information, see the Software section on the Victron Energy website.
Options for programming, data in real time and display of the course
- Modern Apple and Android smartphones, tablets, MacBooks and other devices
- Color Control panel
Battery voltage: 12/24 V automatic choice
Nominal power: 15 a
Nominal PV performance, 12 V 1a, b): 220W
Nominal PV performance, 24V 1A, b): 440W
Max. Short circuit current of the solar system 2): 15a
Automatic load shutdown: Yes, maximum Last 15a
Maximum PV empty voltage: 100V
Top efficiency: 98%
Self -consumption 12V: 25 MA 24V: 15 MA
"Constant" charging voltage (absorption): 14.4V / 28.8 V (adjustable)
"Conservation" charging voltage (float): 13.8V / 27.6V (regulable)
Ladeal gorithm: multi -stage, adaptive
Temperature compensation: -16 mv/° C or -32 mv/° C
Interruption -free/load current: 15 a 20 a
Switch off the load with low voltage: 11.1 V / 22.2 V or 11.8 V / 23.6 V or Battery Life Algorithm
Another connect the load according to low voltage: 13.1 V / 26.2 V or 14 V / 28 V or Battery Life Algorithm
Protection: Polation on the battery (fuse) / output coccyxis / over temperature
Operating temperature: -30 ° C to +60 ° C (full nominal output up to 40 ° C)
Moisture: 95 % not condensing
Data communication sport: ve.direct
Connections: 6 mm² / AWG10
Protection class IP43 (electronic components), IP22 (connection area)
Weight: 0.6 kg
Dimensions: (HXBXT) 100 x 113 x 50 mm
1a) If more PV current is connected, the controller limits the input power
1b) The PV voltage must reach at least the amount of VBAT + 5 V so that the controller takes up the operation.
Then the minimum value of the PV voltage is at VBAT + 1 V.
2) A higher short-circuit current can damage the controller in the event of a flat connection of the PV system.
The wireless solution for set-up, monitor and updated the controller using Apple and Android smartphones, tablets or other devices.
Ve.direct
For a wired data connection with a color control panel, a PC or other devices.
Ultra -fast maximum power point tracking (mppt)
Especially when the sky is covered, when the light intensity changes, an extremely fast MPP regulator improves the energy yield compared to PWM charging controls by up to 30 % and compared to slower MPPT regulators by up to 10 %.
Load exit
An overload of the battery can be prevented by connecting all loads to the load exit.
The load exit separates the loads when the battery has been unloaded to a given voltage value.
Alternatively, an algorithm for intelligent battery management can also be selected: see BatteryLife.
The load exit is short -circuit -proof.
Battery Life: Intelligent battery management
If the solar charging controller is not able to charge the battery within one day to its full capacity, the status of the battery constantly changes between "partially charged" and "end of the discharge".
This operating mode (no regular charging) damages a lead-acid battery within a few weeks or months.
The battery algorithm monitors the charging status of the battery and, if necessary, it takes up the threshold to separate the load every day (i.e., the load is separated earlier) until the energy obtained is sufficient to charge the battery up to almost 100 %. From this point, the threshold value for switching off the load is modulated, so that the charge is almost 100 % reached about once a week.
Programmable battery charging algorithm
For more information, see the Software section on the Victron Energy website.
Day/night taxation and light insulation option
For more information, see the Software section on the Victron Energy website.
Options for programming, data in real time and display of the course
- Modern Apple and Android smartphones, tablets, MacBooks and other devices
- Color Control panel
Battery voltage: 12/24 V automatic choice
Nominal power: 15 a
Nominal PV performance, 12 V 1a, b): 220W
Nominal PV performance, 24V 1A, b): 440W
Max. Short circuit current of the solar system 2): 15a
Automatic load shutdown: Yes, maximum Last 15a
Maximum PV empty voltage: 100V
Top efficiency: 98%
Self -consumption 12V: 25 MA 24V: 15 MA
"Constant" charging voltage (absorption): 14.4V / 28.8 V (adjustable)
"Conservation" charging voltage (float): 13.8V / 27.6V (regulable)
Ladeal gorithm: multi -stage, adaptive
Temperature compensation: -16 mv/° C or -32 mv/° C
Interruption -free/load current: 15 a 20 a
Switch off the load with low voltage: 11.1 V / 22.2 V or 11.8 V / 23.6 V or Battery Life Algorithm
Another connect the load according to low voltage: 13.1 V / 26.2 V or 14 V / 28 V or Battery Life Algorithm
Protection: Polation on the battery (fuse) / output coccyxis / over temperature
Operating temperature: -30 ° C to +60 ° C (full nominal output up to 40 ° C)
Moisture: 95 % not condensing
Data communication sport: ve.direct
Connections: 6 mm² / AWG10
Protection class IP43 (electronic components), IP22 (connection area)
Weight: 0.6 kg
Dimensions: (HXBXT) 100 x 113 x 50 mm
1a) If more PV current is connected, the controller limits the input power
1b) The PV voltage must reach at least the amount of VBAT + 5 V so that the controller takes up the operation.
Then the minimum value of the PV voltage is at VBAT + 1 V.
2) A higher short-circuit current can damage the controller in the event of a flat connection of the PV system.